Please use this identifier to cite or link to this item: http://hdl.handle.net/123456789/5498
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKotyk, M.-
dc.contributor.authorKogut, I.-
dc.contributor.authorSaffouri, Ch.-
dc.date.accessioned2020-04-16T17:28:50Z-
dc.date.available2020-04-16T17:28:50Z-
dc.date.issued2018-12-
dc.identifier.citationKotyk M, Sensory Elements and Devices Operational Diagnostic Blood Glucose Using Near Infrared Radiation / M. Kotyk, I. Kogut, Ch. Saffouri //, PHYSICS AND CHEMISTRY OF SOLIDSTATE - 2017. – V. 18, № 4 (2017) P. 467-471.uk_UA
dc.identifier.issn1729-4428-
dc.identifier.urihttp://hdl.handle.net/123456789/5498-
dc.description.abstractThe article describes a method for measuring the concentration of glucose in human blood by non-invasive method using near-infrared optical technology. In medical practice, glucose concentration in the blood in most cases is measured by invasive methods involving the collection of blood from the finger or vein, while non invasive devices for determining the level of glucose preserve the operational measurement ofblood-borne levels. Invasive methods are expensive and painful. Frequent piercing of fingers causes corns on the skin, and also increases the risk of spreading infectious diseases. Thus, the development of a system of non-invasive measurement of glucose in the blood will be useful for patients with diabetes mellitus. Non-invasive way of measuring glucose levels in human blood is based on the use of pain-free optical technology based on near infrared (BIC) radiation. The proposed system consists of emitters of signals with a wavelength of 940 nm. These optical signals are sent through the earlobe, and the rays passing through it are fixed by a phototransistor located on another part of the device. The concentration of glucose in the blood is determined by analyzing the intensity variation obtained after passing the signal. The results obtained from the developed system show the feasibility of using a non-invasive BIC method for monitoring blood glucose levels. The accuracy of the measurements of the proposed system can be improved by integrating its sensitive and emitting elements based on the SOI of the CMOS structures.uk_UA
dc.language.isoenuk_UA
dc.publisherФІЗИКА І ХІМІЯ ТВЕРДОГО ТІЛАuk_UA
dc.subjectblood glucoseuk_UA
dc.subjectdiabetesuk_UA
dc.subjectnear-infrareduk_UA
dc.subjectnoninvasive methoduk_UA
dc.subjectSOI CMOS-structureuk_UA
dc.titleSensory Elements and Devices Operational Diagnostic Blood Glucose Using Near Infrared Radiationuk_UA
dc.title.alternativeОсобливості неінвазивного вимірювання рівня глюкози в крові із застосування ближнього інфрачервоного випромінюванняuk_UA
dc.typeArticleuk_UA
Appears in Collections:Статті та тези (ФТФ)

Files in This Item:
File Description SizeFormat 
2401-6772-1-PB.pdf800.03 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.